Standard Pump Industrial Drum Pump

    Industrial Pump Tubes

    Our complete range of pump tubes provide an ideal solution for applications ranging from corrosive chemicals to light oils. Pump tubes are available in Polypropylene, PVDF, CPVC, Stainless Steel and Aluminum.

    Centrifugal | Polypropylene

    Engineered for transferring a variety of corrosive liquids.  Robust Polypropylene ensures chemical resistance against light to aggressive chemicals.

    Applications

    • Acetic Acid
    • Sulfuric Acid
    • Hydrochloric Acid (20%)
    • Nitric Acid (20%)
    • Alkalis
    • Ferric Chloride

    image

    Not suitable for pumping flammable or combustible liquids.

    Centrifugal | Stainless Steel

    Centrifugal | CPVC

    Engineered for transferring corrosive chemicals associated with the water treatment industry. Robust CPVC offers excellent durability and chemical resistance.

    Applications

    • Sodium Hypochlorite
    • Calcium Chloride
    • Potassium Hydroxide
    • Calcium Hydroxide
    • Chlorinated Water
    • Sodium Bromide
    Technical Docs

    image

    Not suitable for pumping flammable or combustible liquids.

    Centrifugal | PVDF

    Engineered for transferring highly concentrated and aggressive liquids. Robust PVDF offers excellent durability and chemical resistance.

    Applications

    • Concentrated Nitric Acid
    • Propionic Acid
    • Hydrofluoric Acid
    • Sodium Hypoclorite
    • Sulfuric Acid-66
    • Stearic Acid

    image

    Not suitable for pumping flammable or combustible liquids.

    Centrifugal | Aluminum

    Engineered for transferring non-corrosive liquids such as machining oils, coolants and hydraulic fluid. Robust Aluminum construction offers excellent strength and durability.

    Applications

    • Motor Oil (up to 30 wt)
    • Anti-Freeze
    • Lubricating Oils
    • Light Machining Oils
    • Hydraulic Fluid

    image

    Pumping of flammable or combustible liquids can generate a static electric discharge, causing fire or explosion resulting in injury or death. Read and understand operating instructions before starting this unit. Follow all federal, state and local safety codes including NFPA 30 – NFPA77. Prior to connecting to air supply, install bond and ground wires and check continuity of each wire. A meter reading of one ohm or less is required for safe liquid transfer. Use only approved metallic pump tube, explosion proof or air motor, metallic drum and receiving vessel when pumping flammables. Air motors are not recognized under any current Underwriter’s Laboratory listing program. Consult a qualified engineer for suitability for use in a hazardous area or on flammables.

    Progressive Cavity | Direct Drive

    Engineered to transfer viscous materials from drums, intermediate bulk containers (IBC) and large storage vessels. Utilizing the principle of positive displacement, these pumps deliver a continuous flow of material with little product degradation. Pumps are available with a TEFC electric or air powered motors. Maximum viscosity is 100,000 cps (mPas).

    Applications
    • Polymers
    • Oil & Greases
    • Resins
    • Paints
    • Adhesives
    • Varnishes
    Technical Docs

    image

    Pumping of flammable or combustible liquids can generate a static electric discharge, causing fire or explosion resulting in injury or death. Read and understand operating instructions before starting this unit. Follow all federal, state and local safety codes including NFPA 30 – NFPA77. Prior to connecting to air supply, install bond and ground wires and check continuity of each wire. A meter reading of one ohm or less is required for safe liquid transfer. Use only approved metallic pump tube, explosion proof or air motor, metallic drum and receiving vessel when pumping flammables. Air motors are not recognized under any current Underwriter’s Laboratory listing program. Consult a qualified engineer for suitability for use in a hazardous area or on flammables.

    Industrial Pump Motors

    Standard Pump motors are designed to operate in the most demanding of environments. An extensive line of Explosion Proof, TEFC, Open Drip-Proof and Air motors provide durability and safety regardless of the environment.

    Open Drip-Proof

    Ideally suited for transferring acids and alkalies in corrosive environments. Available in fixed or variable speed control configurations.

    Model Number Power Output lbs (kg)
    SP-280P 110-120V/1/50-60Hz 1 hp (825 w) 10 (4,5)
    SP-280P-V 110-120V/1/50-60Hz 1 hp (825 w) 10 (4,5)
    SP-280P-2 220-240V/1/50-60Hz 1 hp (825 w) 10 (4,5)
    SP-280P-2-V 220-240V/1/50-60Hz 1 hp (825 w) 10 (4,5)
    SP-280P-2NL 220-240V/1/50-60Hz 1 hp (825 w) 10 (4,5)
    SP-280P-2-VNL 220-240V/1/50-60Hz 1 hp (825 w) 10 (4,5)

    Technical Docs

    imageNot suitable for pumping flammable or combustible liquids.

    TEFC

    Ideally suited for transferring acids and alkalies in corrosive environments. Available in fixed or variable speed control configurations.

    Model Number Power Output lbs (kg)
    SP-280P 110-120V/1/50-60Hz 1 hp (825 w) 10 (4,5)
    SP-280P-V 110-120V/1/50-60Hz 1 hp (825 w) 10 (4,5)
    SP-280P-2 220-240V/1/50-60Hz 1 hp (825 w) 10 (4,5)
    SP-280P-2-V 220-240V/1/50-60Hz 1 hp (825 w) 10 (4,5)
    SP-280P-2NL 220-240V/1/50-60Hz 1 hp (825 w) 10 (4,5)
    SP-280P-2-VNL 220-240V/1/50-60Hz 1 hp (825 w) 10 (4,5)

    Technical Docs

    imageNot suitable for pumping flammable or combustible liquids.

    Explosion-Proof

    Air | 1/2 hp

    Engineered for use in heavily corrosive environments or when aggressive fumes are present. Ideally suited for transferring flammable / combustible liquids

    Air | 3/4 hp

    Air | Flange Mount

    Ideally suited for transferring acids and alkalies in corrosive environments. Available in fixed or variable speed control configurations.

    Model Number Power Output lbs (kg)
    SP-280P 110-120V/1/50-60Hz 1 hp (825 w) 10 (4,5)
    SP-280P-V 110-120V/1/50-60Hz 1 hp (825 w) 10 (4,5)
    SP-280P-2 220-240V/1/50-60Hz 1 hp (825 w) 10 (4,5)
    SP-280P-2-V 220-240V/1/50-60Hz 1 hp (825 w) 10 (4,5)
    SP-280P-2NL 220-240V/1/50-60Hz 1 hp (825 w) 10 (4,5)
    SP-280P-2-VNL 220-240V/1/50-60Hz 1 hp (825 w) 10 (4,5)

    Technical Docs

    imageNot suitable for pumping flammable or combustible liquids.

    TEFC | 3 Phase

    Ideal for general industrial use. The totally enclosed fan cooled design is engineered for use in dusty environments or where corrosive fumes are present.

    Model Number Power Output lbs (kg)
    SP-502 190/380//230/460/3/50-60 Hz 3/4 hp (0,56 kw) 56 (25,5)
    SP-522 190/380//230/460/3/50-60 Hz 1 1/2 hp (1,1 kw) 78 lbs (35,5)

    Applications

    • Chemical, Oil, & Gas
    • Food & Beverage
    • Paper and Pulp

    Features

    • TEFC (IP55) enclosure
    • Heavy-gauge steel and gasketed conduit boxes
    • UL and CSA certified

    image

    Not suitable for pumping flammable or combustible liquids.

    Industrial Pump Packages

    The package concept bundles complimentary products to create an out-of-the-box solution.  Each package includes: motor, pump tube, discharge hose, barrel adapter, storage bracket and a hand nozzle.

    Package 1 | CPVC

    Engineered to transfer corrosive chemicals associated with the Water Treatment industry.

    Applications

    • Sodium Hypochlorite
    • Calcium Chloride
    • Potassium Hydroxide
    • Calcium Hydroxide
    • Chlorinated Water
    • Sodium Bromide
    Technical Docs

    image

    Not suitable for pumping flammable or combustible liquids.

    Package 2 | Polypropylene

    Engineered to transfer corrosive chemicals.

    Applications

    • Hydrochloric Acid
    • Acetic Acid
    • Sulfuric Acid
    • Nitric Acid (20%)
    Technical Docs

    image

    Not suitable for pumping flammable or combustible liquids.

    Package 3 | PVDF

    Engineered to transfer concentrated and extremely aggressive chemicals.

    Applications

    • Sulfuric Acid – 66 Baume
    • Concentrated Nitric Acid
    • Hydrofluoric Acid
    • Propionic Acid
    Technical Docs

    image

    Not suitable for pumping flammable or combustible liquids.

    Package 4 | Polypropylene – Meter

    Engineered to safely measure and dispense corrosive chemicals.

    Applications
    • Hydrochloric Acid
    • Acetic Acid
    • Sulfuric Acid
    • Nitric Acid (20%)
    Technical Docs

    image

    Not suitable for pumping flammable or combustible liquids.

    Package 5 | PVDF – Meter

    Engineered to safely measure and dispense corrosive chemicals.

    Applications

    • Sulfuric Acid 66 baume
    • Concentrated Nitric (98%)
    • Hydrofluoric Acid
    • Propionic Acid
    Technical Docs

    image

    Not suitable for pumping flammable or combustible liquids.

    Package 6 | Stainless Steel

    Engineered to transfer mineral acids and suitable chemicals.

    Applications

    • Nitric Acid
    • Citric Acid
    Technical Docs

    image

    Not suitable for pumping flammable or combustible liquids.

    Package 7 | Aluminum

    Engineered to transfer light oils, automotive fluids and lubricants.

    Applications
    • Light Machining Oils
    • Hydraulic Fluid
    • Motor Oil (Up to 30 wt.)
    • Anti-Freeze
    • Lubricating Oil
    Technical Docs

    image

    Not suitable for pumping flammable or combustible liquids.

    Package 8 | EXP – Air

    Designed for transferring flammable/combustible liquids and meets the stringent safety requirements of the chemical processing industry.

    Applications
    • Alcohol
    • Isopropyl Ether
    • Aqueous Ammonia
    • Xylene
    • Petroleum Products
    • Gasoline
    • Toluene​
    • Solvents
    Technical Docs

    image

    Pumping of flammable or combustible liquids can generate a static electric discharge, causing fire or explosion resulting in injury or death. Read and understand operating instructions before starting this unit. Follow all federal, state and local safety codes including NFPA 30 – NFPA77. Prior to connecting to air supply, install bond and ground wires and check continuity of each wire. A meter reading of one ohm or less is required for safe liquid transfer. Use only approved metallic pump tube, explosion proof or air motor, metallic drum and receiving vessel when pumping flammables. Air motors are not recognized under any current Underwriter’s Laboratory listing program. Consult a qualified engineer for suitability for use in a hazardous area or on flammables.

    Package 9 | EXP – Electric

    Designed for transferring flammable/combustible liquids and meets the stringent safety requirements of the chemical processing industry.

    Applications

    • Alcohol
    • Solvents
    • Xylene
    • Isopropyl Ether
    • Aqueous Ammonia
    • Petroleum Products
    Technical Docs

    image

    Pumping of flammable or combustible liquids can generate a static electric discharge, causing fire or explosion resulting in injury or death. Read and understand operating instructions before starting this unit. Follow all federal, state and local safety codes including NFPA 30 – NFPA77. Prior to connecting to air supply, install bond and ground wires and check continuity of each wire. A meter reading of one ohm or less is required for safe liquid transfer. Use only approved metallic pump tube, explosion proof or air motor, metallic drum and receiving vessel when pumping flammables. Air motors are not recognized under any current Underwriter’s Laboratory listing program. Consult a qualified engineer for suitability for use in a hazardous area or on flammables.

    Package 10 | EXP – Air

    Designed for transferring flammable/combustible liquids and meets the stringent safety requirements of the chemical processing industry.

    Applications

    • Alcohol
    • Isopropyl Ether
    • Aqueous Ammonia
    • Xylene
    • Petroleum Products
    • Gasoline
    • Toluene​
    • Solvents
    Technical Docs

    image

    Pumping of flammable or combustible liquids can generate a static electric discharge, causing fire or explosion resulting in injury or death. Read and understand operating instructions before starting this unit. Follow all federal, state and local safety codes including NFPA 30 – NFPA77. Prior to connecting to air supply, install bond and ground wires and check continuity of each wire. A meter reading of one ohm or less is required for safe liquid transfer. Use only approved metallic pump tube, explosion proof or air motor, metallic drum and receiving vessel when pumping flammables. Air motors are not recognized under any current Underwriter’s Laboratory listing program. Consult a qualified engineer for suitability for use in a hazardous area or on flammables.

    Industrial Accessories

    Customize your industrial Drum Pump with selection of accessories. Hand Nozzles provide a safe solution for controlling and dispensing corrosive chemicals.  Barrel Adapters vertically stabilize pumps in drums and Fume Barriers reduce aggressive fumes in the atmosphere.

    Pump Hanger

    The pump hanger is designed for attaching your pump to an overhead lifting device such as a winch.

    Model Number Material Description
    743 SS 316 Engineered to vertically stabilize pump in open top containers

    Wall Bracket

    The Stainless Steel Wall Bracket provides an ideal solution for storing your Drum pump when not in use. Simply secure the bracket to the wall and hang the pump from the Hand Wheel.

    Model Number Material Description
    9006 SS 304 Ideal for Drum Pump Storage

    Quick Disconnect

    The Polypropylene Quick Disconnect is designed to allow pump operators to remove discharge hoses quickly and safely.

    Model Number Material Description
    125A100C Polypropylene 1 1/4″ Thread x 1″ Barb (28 mm x 25mm)

    Suction Strainers

    The chemically resistant Suction Strainers are designed to prevent particulates from entering the pump intake and damaging internal components.

    Model Number Material Mesh Dimensions
    9011 Polypropylene .63″ x .098″ (16×2,5 mm)
    7012 SS316 .58″ x .051″ (14,7×1,3 mm)
    9043 PVDF .63″ x .098″ (16×2,5 mm)

    Fume Barriers

    Chemically resistant Fume Barriers are ideal for applications where aggressive fumes are present. The sealed design contains 99% of aggressive fumes within the drum.

    Model Number Material Description
    9018 Polypropylene 2″ O.D. (51 mm), EPDM Seal
    8804 SS 304 2″ O.D. (51 mm), EPDM Seal

    Barrel Adapters

    Chemically resistamt Barrel Adapters are designed to vertically stablize your pump in a 2″ (50mm) bung.

    Model Number Material Description
    9015 Polypropylene 2″ O.D. (51 mm)
    8802 SS 304 2″ O.D. (51 mm)

    Discharge Hoses

    Model Number Material Description
    9029 Clear PVC 1″ I.D. x 1.25″ O.D. (25 mm x 32 mm)
    Max Temperature: 150ºF (66ºC)
    Max Operating Pressure: 30 psi (2,1 bar)
    Material of Construction: Polyvinyl Chloride
    9032 Clear Braided PVC 1″ I.D. x 1.25″ O.D. (25 mm x 32 mm)
    Max Temperature: 150ºF (66ºC)
    Max Operating Pressure: 75 psi (5,2 bar)
    Material of Construction: Poly-Braid Polyvinyl Chloride
    9034 Goodyear® FabChem™ 1″ (25 mm) I.D. x 1.47 O.D. (25 mm x 37 mm)
    Max Temperature: 150ºF (66ºC)
    Max Operating Pressure: 200 psi (14 bar)
    Material of Construction: Ultra High Molecular Weight Polyethylene
    Note: Designed to be Used for Flammable / Combustible Liquids
    9044 Goodyear® Viper 16™ 1″ (25 mm) I.D. x 1.45″ O.D. (25 mm x 37 mm)
    Max Temperature: 250ºF (121ºC)
    Max Operating Pressure: 200 psi (14 bar)
    Material of Construction: Modified Cross-Linked Polyethylene

    Hand Nozzles

    Model Number Housing Material Hose Barb Size Seal Material
    9070 Polypropylene 1″ (25 mm) Viton
    9071 Polypropylene 3/4″ (19 mm) Viton
    9070e Polypropylene 1″ (25 mm) EPDM
    9071e Polypropylene 3/4″ (19 mm) EPDM
    9090 PVDF 1″ (25 mm) Viton
    9091 PVDF 3/4″ (19 mm) Viton
    9090e PVDF 1″ (25 mm) EPDM
    9091e PVDF 3/4″ (19 mm) EPDM
    9026 SS316 1″ (25 mm) PTFE
    9030 Aluminum 1″ (25 mm) Buna
    ​9030-075 Aluminum 3/4″ (19 mm) Buna

    undefined

    Industrial Pump Lifts

    Battery powered Lift is designed for raising / lowering pumps into drums and tanks. The mobile lift system is ideal for moisture-free environments or where electronic components are protected from overspray and cleaning agents.

    I am text block. Click edit button to change this text. Lorem ipsum dolor sit amet, consectetur adipiscing elit. Ut elit tellus, luctus nec ullamcorper mattis, pulvinar dapibus leo.